The Top Cable TOXFREE MARINE XTCuZ1-K (AS) 0.6/1kV is a specialist halogen-free, fire-retardant, armoured marine power cable designed for fixed installations on ships and offshore units in all locations. Manufactured and tested to IEC 60092-353, this cable carries approvals from five of the world’s leading marine classification societies — DNV, Bureau Veritas, Lloyd’s Register, Germanischer Lloyd, and ABS — making it universally accepted for global maritime and offshore projects. All cable materials are completely halogen-free with low fumes emission and fire-retardant properties, critically important in enclosed ship spaces where toxic fumes during a fire event pose the greatest risk to life. The cable construction features XLPE (Cross-Linked Polyethylene) insulation rated to 90°C, an aluminium-polyester tape inner covering, a tinned copper wire braid/armour for mechanical and electrical protection, and a black thermoplastic polyolefin SHF1 outer sheath. Fire performance meets IEC 60332-1-2 (no flame propagation) and the demanding IEC 60332-3-22 Category A (no fire propagation in bunched cable installations). Halogen-free certification per IEC 60754-1 (acid gas <0.5%), IEC 60754-2 (pH >4.3, conductivity <10 µS/mm), and smoke transmittance >60% per IEC 61034-2 confirm its safety pedigree. Available in configurations from 2-core up to 37-core, covering power, lighting, and control circuit requirements across all marine and offshore applications.
Technical Specifications & Size Variations
Specifications
| Specification | Details |
|---|---|
| Standard | IEC 60092-353 |
| Marine Class Approvals | DNV Bureau Veritas Lloyd’s Register Germanischer Lloyd ABS |
| Nominal Voltage | 0.6/1 kV |
| Max Conductor Operating Temperature | 90°C |
| Lowest Installation Temperature | -15°C |
| Lowest Ambient Temperature (Fixed) | -40°C |
| Short-Circuit Temperature | 250°C (max 5s) |
| Minimum Bending Radius | 6D |
| Conductor | Electrolytic annealed copper, Class 5 (IEC 60228) |
| Insulation | XLPE type HF XLPE-90°C (IEC 60092-360) |
| Inner Covering | Aluminium-polyester tape (halogen free) |
| Armour/Braid | Tinned copper wire braid over aluminium-polyester tape |
| Outer Sheath | Thermoplastic polyolefin SHF1, black (IEC 60092-360) |
| Flame | No flame propagation — IEC 60332-1-2 |
| Fire | No fire propagation — IEC 60332-3-22 Category A |
| Halogen-Free | Acid gas <0.5% (IEC 60754-1) pH >4.3 conductivity <10 µS/mm (IEC 60754-2) |
| Smoke | Light transmittance >60% (IEC 61034-2) |
| COLOUR CODING | — |
| 2 conductors | Blue + Brown |
| 3 conductors | Brown + Black + Grey |
| 4 conductors | Brown + Black + Grey + Blue |
| ≥5 conductors | White numbered Other colours on request |
| AVAILABLE CONFIGURATIONS (Core × Section mm²) | — |
| 2-Core | 2×1.5 2×2.5 2×4 2×6 2×10 2×16mm² |
| 3-Core | 3×1.5 3×2.5 3×4 3×6 3×10 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240mm² |
| 4-Core | 4×1.5 4×2.5 4×4 4×6 4×10 4×16 4×25 4×35 4×50 4×70 4×95 4×120 4×150 4×185 4×240mm² |
| 5-Core | 5×1.5 5×2.5 5×4 5×6 5×10 5×16 5×25 5×35 5×50mm² |
| Multi | 7×1.5 7×2.5 10×1.5 12×1.5 12×2.5 14×1.5 16×1.5 19×1.5 19×2.5 24×1.5 27×1.5 27×2.5 37×1.5mm² |
SAMPLE CURRENT RATINGS (Open Air, 45°C ambient)
| Specification | Details |
|---|---|
| 3×2.5mm² | 31A 3×6mm²: 55A 3×16mm²: 87A 3×35mm²: 137A |
| 3×70mm² | 214A 3×120mm²: 301A 3×240mm²: 468A |
| Temp Correction Factors | 35°C ×1.10 40°C ×1.05 50°C ×0.94 60°C ×0.82 |